Overview


The ETC6081 O2 Trim interface and software enables closed-loop oxygen trim on ETC controllers by integrating a flue-mounted oxygen probe. It continuously trims the fuel:air ratio based on measured flue oxygen to improve combustion efficiency and emissions performance in industrial and commercial burner and boiler applications.

Core functions


  • Integrates a flue oxygen probe with ETC controllers to provide continuous O2 feedback
  • Automatically trims the fuel:air ratio in real time to maintain efficient combustion under changing load
  • Compensates for combustion variables such as barometric pressure, humidity, and gas pressure to stabilise excess air
  • Provides an intuitive automatic trim set-up routine to reduce commissioning time
  • Supports assignable oxygen and temperature alarm limits for monitoring and protection
  • Enables boiler efficiency and calculated CO2 display and retransmission when the 6086 air temperature sensor is included in the peripheral configuration

Key technical features


  • Oxygen trim interface and software layer for ETC controllers to enable closed-loop O2 trim
  • Compatible for use across multiple fuels including natural gas, oil, and LPG
  • Uses the ETC6083 oxygen probe design with no moving parts
  • No pumped reference air required by the probe design
  • Stainless steel probe construction for flue installation duty
  • 6 micron sintered stainless steel filter for protection in flue environments
  • Integrated thermocouple within the probe assembly
  • Suitable for flue gas temperatures up to 540°C (1000°F)
  • Probe size range to suit flue sizes from 0.3 m to 4.0 m across
  • Fast probe response characteristics to support continuously modulating burners

Options and customization


  • Select ETC6083 probe size to match the target flue size (0.3 m to 4.0 m across)
  • Configure oxygen alarm limits to suit site requirements
  • Configure temperature alarm limits to suit site requirements
  • Add the 6086 air temperature sensor in the peripheral configuration to enable boiler efficiency and calculated CO2 display and retransmission

Typical applications


  • Industrial and commercial boiler rooms using ETC controllers where efficiency and emissions depend on stable excess-air control
  • Continuously modulating burners where fuel:air ratio can drift without closed-loop oxygen feedback
  • Retrofit oxygen trim upgrades for ETC-controlled systems operating on natural gas, oil, or LPG

Documents & Downloads


  • InnoBurn - Company Profile TR 🇹🇷
  • ETC6081 - Product Catalogue TR 🇹🇷

  • InnoBurn - Company Profile EN 🇺🇸
  • ETC6081 - Product Catalogue EN 🇺🇸

  • InnoBurn - Company Profile AR 🇸🇦
  • ETC6081 - Product Catalogue AR 🇸🇦

Would you like to know more ? 

If you need further information, samples, a quote or advice for a project, please fill out the form below and we would be happy to help.